{"id":951852,"date":"2023-07-11T07:00:00","date_gmt":"2023-07-11T14:00:00","guid":{"rendered":"https:\/\/www.microsoft.com\/en-us\/research\/?p=951852"},"modified":"2023-07-06T16:53:56","modified_gmt":"2023-07-06T23:53:56","slug":"microsoft-at-icalp-2023-deploying-cloud-capacity-robustly-against-power-failures","status":"publish","type":"post","link":"https:\/\/www.microsoft.com\/en-us\/research\/blog\/microsoft-at-icalp-2023-deploying-cloud-capacity-robustly-against-power-failures\/","title":{"rendered":"Microsoft at ICALP 2023: Deploying cloud capacity robustly against power failures"},"content":{"rendered":"\n<p class=\"has-text-align-center h6\"><em>This research paper was accepted by the&nbsp;<\/em><a class=\"msr-external-link glyph-append glyph-append-open-in-new-tab glyph-append-xsmall\" href=\"https:\/\/icalp2023.cs.upb.de\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>50<sup>th<\/sup> EATCS International Colloquium on Automata, Languages and Programming (ICALP 2023)<\/em><span class=\"sr-only\"> (opens in new tab)<\/span><\/a><em>, which is dedicated to advancing the field of theoretical computer science.<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1400\" height=\"788\" src=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1.jpg\" alt=\"Image that includes the blog title, \u201dMicrosoft at ICALP 2023: Deploying cloud capacity robustly against power failures.\u201d It also shows the ICALP 2023 logo, which is in Paderborn, Germany, and an image of the first page of the published paper. The background is a subtle abstract design.\" class=\"wp-image-952437\" srcset=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1.jpg 1400w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-300x169.jpg 300w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-1024x576.jpg 1024w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-768x432.jpg 768w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-1066x600.jpg 1066w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-655x368.jpg 655w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-343x193.jpg 343w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-240x135.jpg 240w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-640x360.jpg 640w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-960x540.jpg 960w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-1280x720.jpg 1280w\" sizes=\"auto, (max-width: 1400px) 100vw, 1400px\" \/><\/figure>\n\n\n\n<p>In the rapidly evolving landscape of cloud computing, escalating demand for cloud resources is placing immense pressure on cloud providers, driving them to consistently invest in new hardware to accommodate datacenters\u2019 expanding capacity needs. Consequently, the ability to power all this hardware has emerged as a key bottleneck, as devices that power datacenters have limited capacity and necessitate efficient utilization. Efficiency is crucial, not only to lower operational costs and subsequently prices to consumers, but also to support the sustainable use of resources, ensure their long-term availability, and <a class=\"msr-external-link glyph-append glyph-append-open-in-new-tab glyph-append-xsmall\" href=\"https:\/\/blogs.microsoft.com\/blog\/2020\/01\/16\/microsoft-will-be-carbon-negative-by-2030\/\" target=\"_blank\" rel=\"noopener noreferrer\">preserve the environment<span class=\"sr-only\"> (opens in new tab)<\/span><\/a> for future generations.<\/p>\n\n\n\n<p>At the same time, it is of the utmost importance to ensure power availability for servers, particularly in the event of a power device failure. <a href=\"https:\/\/www.microsoft.com\/en-us\/research\/publication\/flex-high-availability-datacenters-with-zero-reserved-power\/\">Modern datacenter architectures<\/a> <a href=\"https:\/\/www.microsoft.com\/en-us\/research\/publication\/flex-high-availability-datacenters-with-zero-reserved-power\/\"><\/a>have adopted a strategy to mitigate this risk by avoiding the reliance on a single power source for each server. Instead, each server is powered by two devices. Under normal operations, a server draws half its required power from each device. In the event of a failover, the remaining device steps in to support the server\u2019s full power demand, potentially operating at an increased capacity during the failover period.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure1.png\" alt=\"Two diagrams depicting the power allocation of three servers (1, 2, and 3) to three power devices (a, b, and c). The first diagram shows the allocation in normal operations with server 1 taking half of its power from device a and half from device b, server 2 being split half and half on devices a and c, and server 3 on devices b and c. The second diagram shows the failover due to device c becoming unavailable; now device a must support the full power of server 2, and device b the full power of server 3, server 1 is still taking power from both devices a and b.\" class=\"wp-image-953517\" width=\"752\" height=\"270\" srcset=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure1.png 1002w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure1-300x108.png 300w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure1-768x276.png 768w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure1-240x86.png 240w\" sizes=\"auto, (max-width: 752px) 100vw, 752px\" \/><figcaption class=\"wp-element-caption\">Figure 1: This diagram depicts the power allocation of three servers (1, 2, and 3) to the power devices (a, b, and c) that serve them, during both normal operations and in a failover scenario. The height of each power device represents its capacity, and the height of each server within those power devices shows its power consumption. During failover, the servers have fewer devices from which to draw power, resulting in increased energy consumption from the resources available.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n\t<div class=\"border-bottom border-top border-gray-300 mt-5 mb-5 msr-promo text-center text-md-left alignwide\" data-bi-aN=\"promo\" data-bi-id=\"1141385\">\n\t\t\n\n\t\n\t<div class=\"row pt-3 pb-4 align-items-center\">\n\t\t\t\t\t\t<div class=\"msr-promo__media col-12 col-md-5\">\n\t\t\t\t<a class=\"bg-gray-300 display-block\" href=\"https:\/\/ai.azure.com\/labs\" aria-label=\"Azure AI Foundry Labs\" data-bi-cN=\"Azure AI Foundry Labs\" target=\"_blank\">\n\t\t\t\t\t<img decoding=\"async\" class=\"w-100 display-block\" src=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2025\/06\/Azure-AI-Foundry_1600x900.jpg\" \/>\n\t\t\t\t<\/a>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t<div class=\"msr-promo__content p-3 px-5 col-12 col-md\">\n\n\t\t\t\t\t\t\t\t\t<h2 class=\"h4\">Azure AI Foundry Labs<\/h2>\n\t\t\t\t\n\t\t\t\t\t\t\t\t<p id=\"azure-ai-foundry-labs\" class=\"large\">Get a glimpse of potential future directions for AI, with these experimental technologies from Microsoft Research.<\/p>\n\t\t\t\t\n\t\t\t\t\t\t\t\t<div class=\"wp-block-buttons justify-content-center justify-content-md-start\">\n\t\t\t\t\t<div class=\"wp-block-button\">\n\t\t\t\t\t\t<a href=\"https:\/\/ai.azure.com\/labs\" aria-describedby=\"azure-ai-foundry-labs\" class=\"btn btn-brand glyph-append glyph-append-chevron-right\" data-bi-cN=\"Azure AI Foundry Labs\" target=\"_blank\">\n\t\t\t\t\t\t\tAzure AI Foundry\t\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div><!--\/.msr-promo__content-->\n\t<\/div><!--\/.msr-promo__inner-wrap-->\n\t<\/div><!--\/.msr-promo-->\n\t\n\n\n<h2 class=\"wp-block-heading\" id=\"challenges-of-optimizing-power-allocation\">Challenges of optimizing power allocation<\/h2>\n\n\n\n<p>In our paper, \u201c<a href=\"https:\/\/www.microsoft.com\/en-us\/research\/publication\/online-demand-scheduling-with-failovers\/\" target=\"_blank\" rel=\"noreferrer noopener\">Online Demand Scheduling with Failovers<\/a>,\u201d which we\u2019re presenting at the <a class=\"msr-external-link glyph-append glyph-append-open-in-new-tab glyph-append-xsmall\" href=\"https:\/\/icalp2023.cs.upb.de\/\" target=\"_blank\" rel=\"noopener noreferrer\">50<sup>th<\/sup> EATCS International Colloquium on Automata, Languages and Programming, (ICALP 2023)<span class=\"sr-only\"> (opens in new tab)<\/span><\/a>, we explore a simplified model that emphasizes power management to determine how to optimally place servers within a datacenter. Our model contains multiple power devices and new servers (demands), where each power device has a normal capacity of 1 and a larger failover capacity, B. Demands arrive over time, each with a power requirement, and we must irrevocably assign each demand to a pair of power devices with sufficient capacity. The goal is to maximize the total power of the assigned demands until we are forced to reject a demand due to lack of power. This helps us maximize the usage of the available power devices.<\/p>\n\n\n\n<p>One crucial aspect of this model is the presence of uncertainty. We assign capacity for each demand without knowing future needs. This uncertainty adds complexity, as selection of device pairs for each demand must be carefully executed to avoid allocations that could hinder the placement of future demands. Figure 2 provides an illustration.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"860\" height=\"230\" src=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure2.png\" alt=\"Two diagrams, each showing four power devices a, b, c, and d, and demands that have per-device power requirement \u00bc each. The first diagram is labelled \u201cbad assignment\u201d and has two demands that take their power from a and b, and two demands from c and d. The second diagram is labelled \u201cgood assignment\u201d and has six demands total, each on a different pair of devices.\" class=\"wp-image-953520\" srcset=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure2.png 860w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure2-300x80.png 300w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure2-768x205.png 768w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure2-240x64.png 240w\" sizes=\"auto, (max-width: 860px) 100vw, 860px\" \/><figcaption class=\"wp-element-caption\">Figure 2: This example shows four power devices a, b, c, and d, with failover capacity B=1, and six demands that arrive sequentially, with a per-device power requirement of \u00bc each. Suppose four demands have arrived so far. The example on the left represents a bad assignment that cannot accept the remaining two demands. This is because if we placed an additional demand, say, on device a, its failover capacity would be exceeded if b failed. On the other hand, a good assignment, depicted on the right, allows for the placement of all six demands.<\/figcaption><\/figure>\n\n\n\n<p>The example in Figure 2 suggests that we should spread the demands across device pairs. Otherwise, pairs with large loads could have a big impact on the remaining devices should one device fail. On the other hand, there is a danger in spreading out the demands too much and not leaving enough devices free, as shown in Figure 3.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"860\" height=\"220\" src=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure3.png\" alt=\"Two diagrams, each showing four power devices a, b, c, and d, and demands that have per-device power requirement either a small amount epsilon or 0.5. The first diagram is labelled \u201cbad assignment\u201d and has six demands of power epsilon that are each assigned on a different pair of devices. The second diagram is labelled \u201cgood assignment\u201d and has six demands of power epsilon assigned to the devices a and b, and one demand of power 0.5 assigned to the devices c and d.\" class=\"wp-image-953523\" srcset=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure3.png 860w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure3-300x77.png 300w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure3-768x196.png 768w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/07\/ICALP_Blog_figure3-240x61.png 240w\" sizes=\"auto, (max-width: 860px) 100vw, 860px\" \/><figcaption class=\"wp-element-caption\">Figure 3: This example involves four power devices, labeled a, b, c, and d, each with failover capacity B=1. The scenario also includes seven demands that arrive sequentially, with the first six requiring little power per device (epsilon = 0.01 units of power, for example), and the last requiring 0.5 units of power. In (a), when the small demands are distributed across pairs, the final demand cannot be accommodated because the failover capacity is exceeded. However, by grouping the small demands on a single pair of power devices, as shown in (b), all demands can be successfully accommodated.<\/figcaption><\/figure>\n\n\n\n<p>In analyzing the examples in Figures 2 and 3, it becomes clear that striking the right balance is crucial. This entails effectively distributing demands across pairs to minimize any consequences resulting from failovers while also ensuring the availability of an adequate number of devices to meet future demand. Attaining the optimal allocation avoids prematurely ending up with an unassignable demand.<\/p>\n\n\n\n<p>To tackle this challenge, we developed algorithms that are guaranteed to efficiently utilize the available power resources. In fact, our allocations are provably close to optimal, even without upfront knowledge of the demands. Our algorithms essentially conquer the inherent uncertainty of the problem.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"optimizing-for-the-worst-case-scenario\">Optimizing for the worst-case scenario<\/h2>\n\n\n\n<p>Our first algorithm takes a conservative approach, protecting against the worst-case scenario. It guarantees that, regardless of the sequence of demand requests, it will utilize at least half of the power when compared with an optimal solution that has prior knowledge of all demands. As we show in the <a href=\"https:\/\/www.microsoft.com\/en-us\/research\/publication\/online-demand-scheduling-with-failovers\/\" target=\"_blank\" rel=\"noreferrer noopener\">paper<\/a>, this result represents the optimal outcome achievable in the most challenging instances.<\/p>\n\n\n\n<p>To effectively strike a balance between distributing demands across devices and ensuring sufficient device availability, the goal of this algorithm is to group demands based on their power requirements. Each group of demands is then allocated separately to an appropriately sized collection of devices. The algorithm aims to consolidate similar demands in controlled regions, enabling efficient utilization of failover resources. Notably, we assign at most one demand per pair of devices in each collection, except in the case of minor demands, which are handled separately.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"optimizing-for-real-world-demand\">Optimizing for real-world demand<\/h2>\n\n\n\n<p>Because the previous algorithm prioritizes robustness against the worst-case demand sequences, it may unintentionally result in underutilizing the available power by a factor of \u00bd, which is unavoidable in that setting. However, these worst-case scenarios are uncommon in typical datacenter operations. Accordingly, we shifted our focus to a more realistic model where demands arise from an unknown probability distribution. We designed our second algorithm in this stochastic arrival model, demonstrating that as the number of demands and power devices increases, its assignment progressively converges to the optimal omniscient solution, ensuring that no power is wasted.<\/p>\n\n\n\n<p>To achieve this, the algorithm learns from historical data, enabling informed assignment decisions based on past demands. By creating \u201callocation templates\u201d derived from previous demands, we learn how to allocate future demands. To implement this concept and prove its guarantee, we have developed new tools in probability and optimization that may be valuable in addressing similar problems in the future.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Efficiency is vital in the face of escalating demand for cloud resources. And efficient power management strategies address the bottleneck of power availability in datacenters. Learn how we optimize power allocation to support sustainable resource usage.<\/p>\n","protected":false},"author":42183,"featured_media":952437,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"msr-url-field":"","msr-podcast-episode":"","msrModifiedDate":"","msrModifiedDateEnabled":false,"ep_exclude_from_search":false,"_classifai_error":"","msr-author-ordering":null,"msr_hide_image_in_river":0,"footnotes":""},"categories":[1],"tags":[],"research-area":[13561,13547],"msr-region":[],"msr-event-type":[],"msr-locale":[268875],"msr-post-option":[243984],"msr-impact-theme":[],"msr-promo-type":[],"msr-podcast-series":[],"class_list":["post-951852","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-research-blog","msr-research-area-algorithms","msr-research-area-systems-and-networking","msr-locale-en_us","msr-post-option-blog-homepage-featured"],"msr_event_details":{"start":"","end":"","location":""},"podcast_url":"","podcast_episode":"","msr_research_lab":[199565],"msr_impact_theme":[],"related-publications":[],"related-downloads":[],"related-videos":[],"related-academic-programs":[],"related-groups":[144927,282170,569136],"related-projects":[1114452,615975],"related-events":[],"related-researchers":[{"type":"user_nicename","value":"Konstantina Mellou","user_id":38874,"display_name":"Konstantina Mellou","author_link":"<a href=\"https:\/\/www.microsoft.com\/en-us\/research\/people\/kmellou\/?lang=ko-kr\" aria-label=\"Konstantina Mellou \ub300\ud55c \ud504\ub85c\ud544 \ud398\uc774\uc9c0 \ubc29\ubb38\">Konstantina Mellou<\/a>","is_active":false,"last_first":"Mellou, Konstantina","people_section":0,"alias":"kmellou"},{"type":"user_nicename","value":"Marco Molinaro","user_id":42204,"display_name":"Marco Molinaro","author_link":"<a href=\"https:\/\/www.microsoft.com\/en-us\/research\/people\/mmolinaro\/?lang=ko-kr\" aria-label=\"Marco Molinaro \ub300\ud55c \ud504\ub85c\ud544 \ud398\uc774\uc9c0 \ubc29\ubb38\">Marco Molinaro<\/a>","is_active":false,"last_first":"Molinaro, Marco","people_section":0,"alias":"mmolinaro"},{"type":"guest","value":"rudy-zhou","user_id":"951870","display_name":"Rudy Zhou","author_link":"<a href=\"https:\/\/rudyzhou.github.io\/\" aria-label=\"Rudy Zhou \ub300\ud55c \ud504\ub85c\ud544 \ud398\uc774\uc9c0 \ubc29\ubb38\">Rudy Zhou<\/a>","is_active":true,"last_first":"Zhou, Rudy","people_section":0,"alias":"rudy-zhou"}],"msr_type":"Post","featured_image_thumbnail":"<img width=\"960\" height=\"540\" src=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-960x540.jpg\" class=\"img-object-cover\" alt=\"Image that includes the blog title, \u201dMicrosoft at ICALP 2023: Deploying cloud capacity robustly against power failures.\u201d It also shows the ICALP 2023 logo, which is in Paderborn, Germany, and an image of the first page of the published paper. The background is a subtle abstract design.\" decoding=\"async\" loading=\"lazy\" srcset=\"https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-960x540.jpg 960w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-300x169.jpg 300w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-1024x576.jpg 1024w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-768x432.jpg 768w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-1066x600.jpg 1066w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-655x368.jpg 655w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-343x193.jpg 343w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-240x135.jpg 240w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-640x360.jpg 640w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1-1280x720.jpg 1280w, https:\/\/www.microsoft.com\/en-us\/research\/wp-content\/uploads\/2023\/06\/ICALP-2023-BlogHeroFeature-1400x788-1.jpg 1400w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/>","byline":"<a href=\"https:\/\/www.microsoft.com\/en-us\/research\/people\/kmellou\/\" title=\"Go to researcher profile for Konstantina Mellou\" aria-label=\"Go to researcher profile for Konstantina Mellou\" data-bi-type=\"byline author\" data-bi-cN=\"Konstantina Mellou\">Konstantina Mellou<\/a>, <a href=\"https:\/\/www.microsoft.com\/en-us\/research\/people\/mmolinaro\/\" title=\"Go to researcher profile for Marco Molinaro\" aria-label=\"Go to researcher profile for Marco Molinaro\" data-bi-type=\"byline author\" data-bi-cN=\"Marco Molinaro\">Marco Molinaro<\/a>, and <a href=\"https:\/\/rudyzhou.github.io\/\" title=\"Go to researcher profile for Rudy Zhou\" aria-label=\"Go to researcher profile for Rudy Zhou\" data-bi-type=\"byline author\" data-bi-cN=\"Rudy Zhou\">Rudy Zhou<\/a>","formattedDate":"July 11, 2023","formattedExcerpt":"Efficiency is vital in the face of escalating demand for cloud resources. And efficient power management strategies address the bottleneck of power availability in datacenters. Learn how we optimize power allocation to support sustainable resource usage.","locale":{"slug":"en_us","name":"English","native":"","english":"English"},"_links":{"self":[{"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/posts\/951852","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/users\/42183"}],"replies":[{"embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/comments?post=951852"}],"version-history":[{"count":24,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/posts\/951852\/revisions"}],"predecessor-version":[{"id":954090,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/posts\/951852\/revisions\/954090"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/media\/952437"}],"wp:attachment":[{"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/media?parent=951852"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/categories?post=951852"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/tags?post=951852"},{"taxonomy":"msr-research-area","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/research-area?post=951852"},{"taxonomy":"msr-region","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-region?post=951852"},{"taxonomy":"msr-event-type","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-event-type?post=951852"},{"taxonomy":"msr-locale","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-locale?post=951852"},{"taxonomy":"msr-post-option","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-post-option?post=951852"},{"taxonomy":"msr-impact-theme","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-impact-theme?post=951852"},{"taxonomy":"msr-promo-type","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-promo-type?post=951852"},{"taxonomy":"msr-podcast-series","embeddable":true,"href":"https:\/\/www.microsoft.com\/en-us\/research\/wp-json\/wp\/v2\/msr-podcast-series?post=951852"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}